Verify® Dual Species Self Contained Biological Indicators
Item ID: CMLS3060
Manufacturer Part #:
S3060
UNSPC CODE:
42281803
Blue to Yellow Indicator Change, Steam / Ethylene Oxide Gas Sterilization Compatibility, 250 to 270°F Temperature Range, 24 / 48 hrs Read Time Time To Result, Verify® Dual Species Self Contained Biological Indicators (100 per Box)
FEATURES & BENEFITS
- 24-hour final results for steam sterilization
- 48-hour final results for EO sterilization
- Sturdy design prevents premature activation
- For routine monitoring, qualification and release of loads containing implantable devices. Vivid color change of pH incubation to indicate microbial growth
- Fast release of processed items
- Reduces inventory
- pH indicator makes positives easier to identify
- Reduces chances for false positives due to poor aseptic transfer technique
Find Verify® Dual Species Self Contained Biological Indicators ➤ Canada Medical | Value Priced | Timely Delivery | Great Service
- Verify® Dual Species Self Contained Biological Indicators
- Indicator Change: Blue to Yellow
- Sterilization Compatibility: Steam / Ethylene Oxide Gas
- Temperature Range: 250 to 270°F
- Time To Result: 24 / 48 hrs Read Time
- VERIFY Dual Species Self-Contained Biological Indicators (SCBIs) are for use in monitoring steam sterilization and ethylene oxide (EO) sterilization processes. The VERIFY Dual Species Self-Contained BI is designed to be sealed after processing, reducing the risk of contamination or growth medium evaporation. The vial label also contains a process indicator for steam and EO sterilization processes, verifying contact with sterilant How VERIFY Dual Species Self-Contained Biological Indicators Work Each SCBI is completely self-contained within a vial and contains a disc inoculated with dual species bacterial spores (Geobacillus stearothermophilus and Bacillus atrophaeus) and an ampoule of specially formulated soybean casein digest growth medium with a pH indicator Following incubation, a vivid color change from blue/purple to yellow and/or vial becoming turbid gives evidence of microbial growth. If no microbial growth occurs, the vial remains blue and without turbidity Why VERIFY Dual Species Self-Contained Biological Indicators Vivid color change of pH indicator during incubation to indicate microbial growth Complete system is self-contained, including BI, media and pH indicator Reduces chances for false positives due to poor aseptic transfer technique Sturdy design prevents premature activation